The IS WindObserver is an Intrinsically Safe anemometer, developed specifically for use in hazardous areas and in particular for offshore applications.
- Approved to EEx ia IIC T5 for Hazardous Areas
- 2-axis Ultrasonic Wind Speed and Direction Sensor
- Up to 75m/s Wind Speeds
View More Information
The system combines the latest development in technology with Gill's considerable expertise in the production of solid state anemometers. The Intrinsically Safe WindObserver is a lightweight, robust unit, completely sealed and constructed in stainless steel.
With a low start-up speed (0.01 m/s) and no moving parts, the IS WindObserver Intrinsically Safe anemometer exhibits significant benefits over standard three cup anemometers. Approved to EEx ia IIC T5, this Intrinsically Safe anemometer is ideal for use in hazardous areas, requiring no calibration or maintenance.
Wind speed and direction data is provided via a RS422 or RS232 bi-directional link and the output may be configured by the user to provide a variety of communication formats, including a choice of units of measure and averaging periods. Sophisticated error checking and a fault reporting system are supplied as standard, ensuring the user's confidence in the reported data.
Send a Product Enquiry
- Features
- Specifications
- Documentation
- Anemometer Range
- 2-axis Intrinsically Safe anemometer providing wind speed and direction data
- 0-75m/s wind speed
- 0-359º wind direction range (no dead band)
- Approved to EEx ia IIC T5 for Hazardous Areas
- No onshore maintenance required
- Free data logging software
- Robust stainless-steel casing
- Factory calibrated for the life of the product
|
| Wind Speed |
| Range |
0-75m/s (0-168mph) |
| Starting Threshold |
0.01m/s |
| Accuracy |
±2% @ 12m/s (1% for turbine control) |
| Resolution |
0.01m/s |
| Offset |
±0.01m/s |
| Wind Direction |
| Range |
0-359º (no dead band) |
| Accuracy |
±2% @ 12m/s (1% for turbine control) |
| Resolution |
1º |
| Measurement |
| Ultrasonic Output Rate |
1 Hz |
| Parameters |
Wind Speed & Direction |
| Units |
m/s, knots, mph, kph, ft/min |
| Averaging |
3sec, 5sec, 10sec |
| Power Requirement |
| Anemometer only |
20-30VDC (60mA max, 50mA average) |
| Heating |
Max 7A @ 24V AC or DC |
| Digital Output |
| Communication |
RS422 / RS232 from power supply & interface
RS422 from anemometer |
| Baud Rates |
1200, 2400, 4800, 9600, 19200, 38400 |
| Formats |
8 bit data; odd; even or no parity |
| Anemometer Status |
Supplied as part of standard message |
| Mechanical |
| External Construction |
316 Stainless Steel |
| Size |
381mm x 213mm |
| Weight |
1.6kg (without cable) |
| Environmental |
| Protection Class |
IP66 (NEMA4X) |
| Humidity |
5% to 100% RH |
| Precipitation |
300mm/hr |
| EMC |
BS EN 50081-1: 1992 (emission class B)
BS EN 50082-2: 1992 (Immunity) |
| Approvals |
| Standards |
EEx ia IIC T5
Complies with ATEX directive |
| Anemometer Range Information |
|
|
|
|
Software
|
|
|
|
|
|
|
|

|
|
 |