Professional Weather Station

MetPak Pro

  • Wind Speed & Direction
  • Air Temperature, Dew Point
  • Humidity, Barometric Pressure
  • 2 Analogue Inputs, 1 Digital Input
  • 1 PRT Input
MetPak Pro Weather Station

MetPak Pro Weather Station

MetPak Pro System Diagram

MetPak Pro is a professional weather station, capable of monitoring the most essential weather parameters with the additional ability to connect up to four external measurement devices.

The system combines a WindSonic ultrasonic wind speed and direction sensor, a barometric pressure sensor and Rotronic Hygroclip HC2-S3 temperature/humidity probe. Up to four additional sensors can be connected via one PRT input (temperature sensor), one digital input (rain gauge) and two analogue inputs suitable for a range of sensors (e.g water level sensor, pyranometer, pressure sensor, soil temperature sensor etc).

The system features a rugged U-bolt mounting clamp, suitable for attachment to any vertical pipe up to 50mm diameter.

Weather Station Software

The MetPak Pro weather station is provided with MetSet configuration software and MetView display software:

MetView Display Software for MetPak Pro

MetView Display Software

MetView is supplied free of charge with the MetPak Pro, offering a clear, intuitive display of the current weather conditions.

Download MetView Display Software

MetView will not only show data provided by the MetPak Pro (Temperature, Humidity, Dew Point, Pressure, Wind Speed and Wind direction) but can be expanded to display data from other sensors connected to the system.

MetSet Configuration Software for MetPak Pro

MetSet Configuration Software

MetSet is a free software package that allows the user to configure the output and display data provided by the MetPak Pro.

Download MetSet Display Software

The simple interface features a range of drop-down selection boxes, providing the ability to enable or disable existing sensors and adjust output rates. MetSet also allows the user to add additional sensors to the MetPak Pro, with full control over the sensor ID, units of measure and range.

MetPak Pro Weather Station Technical Information

  • Features
  • Specifications
  • Typical Applications
  • Documentation
  • Part Numbers
  • Wind Speed & Direction Measurement
  • Air Temperature Measurement
  • Relative Humidity Measurement
  • Barometric Pressure Measurement
  • Dew Point Measurement
  • PRT Input for additional temperature sensor
  • Digital Input for tipping bucket rain gauge
  • 2 x Analogue inputs, suitable for water level sensor, pyranometer, pressure sensor, soil temperature sensor etc.
Wind Measurement
Parameters
Wind speed & direction or U & V (Vectors)
Units of measure
m/s, knots, mph, kph, ft/min
Wind Speed Range
0-60m/s (134 mph)
Wind Speed Accuracy
±2% @12m/s
Wind Speed Resolution
0.01m/s (0.02 mph)
Wind Direction Range
0 to 359º - No dead band
Wind Direction Accuracy
±3º @12m/s
Wind Direction Resolution
Air Temperature
Air Temperature
Pt100 1/3 Class B
Range
-35ºC to +70ºC
Accuracy
±0.1ºC
Resolution
0.1ºC (0.1ºF)
Units of measure
ºC or ºF
Relative Humidity
Range
0-100% RH
Accuracy
±0.8% @23ºC
Resolution
0.1% RH
Units of measure
% RH
Compensated for temperature dependency
Barometric Pressure
Range
600-1100hPa
Accuracy
±0.5hPa
Resolution
0.1hPa
Units of measure
hPa, mbar, mmHg, inHg
Compensated for temperature dependency -20ºC to +70ºC
Dew Point
Resolution
0.1ºC (0.1ºF)
Units of measure
ºC or ºF
Accuracy
±0.15ºC (23ºC ambient temp @20ºC dew point)
Software
MetView
Display and of data logging software
MetSet
Configuration software
Power Supply
Input voltage
4.5V to 30V d.c.
Current
<26mA (Output 1 second) @12V d.c.
SDI-12
Input Voltage
12 V nominal (9.6-16V d.c.)
Current
<12mA Low power operation
Outputs
Digital outputs
RS232, RS422, RS485* or SDI-12 (user selectable)
Baud rates
9600-57600 (ASCII) or 1200 (SDI-12)
Protocols
ASCII or SDI-12 V1.3
Data output
1s, 2s, 4s or polled mode
* 2 wire point to point
Inputs
Analogue 1
0-5 V or 4-20mA loop or self powered
Analogue 2
0-5 V or 4-20mA loop or self powered
MetPak Pro A-D Conversion
12 bit resolution with an accuracy of ± 0.1% of reading +35µV offset
PRT
4 Wire Pt100 conforms to IEC 60751
Rain Gauge
Contact closure (tipping bucket rain gauge) Capable of capturing events up to 10Hz
Environmental
Protection class
IP65
EMC
EN 61326
Operating temperature
-35ºC to +70ºC
Storage temperature
-40ºC to +80ºC
Operating humidity
0% to 100% humidity
Mechanical
External construction
UV stabilised white thermoplastic
Fittings
Gloss white painted aluminium mounting bracket (with moulded plastic V-block and stainless steel U-bolt), which allows attachment to a vertical pipe of any diameter between 25mm and 50mm
Weight
1.1kg (including bracket)
Specifications may be subject to change without prior notice.
  • Golf Club Weather Monitoring & Club Safety
  • HVAC & Building Automation Control
  • Agricultural Weather Station
  • Government & Emergency Management
  • Education & Environmental Research
  • Pollution Control
  • Weather Forcasting
  • Power and Smart Grid Solutions
  • Sports & Recreation Environmental Observation
  • Transport & Aviation Weather Monitoring
MetPak Pro Weather Station Part Numbers & Options
Systems
MetPak Pro Weather Station
1723-PK-200
MetPak Pro Accessories
1.8m USB Configuration Cable
1723-10-051
15m Power & Communications Cable (6 pair)
1723-10-053
Junction Box PCB
1723-PK-202
Pole Mount Junction Box Brackets (pack of 4)
1723-PK-203
Panel Mount Junction Box Feet (pack of 4)
1723-PK-204

Weather Station Enquiry

Weather Station Photos

  • weather station image
  • weather station image
  • weather monitoring application photo
  • cave weather station
  • weather station